Manufacturer since 1993 · Shenzhen, China · Sales & support for North America and Europe sales@grtbusbars.com+1 514 607 5940
Home / Products
Made to your drawing

Products

Four product families cover most high-current connections inside power electronics. Every part is custom. If you need something in between, ask us.

Rigid conductors

Copper & aluminum busbars

Made from T2 copper or 1060 aluminum by cutting, stamping, bending, riveting, welding and plating. Typical parts include inverter and capacitor busbars, wind-power lead bars and generator copper rings.

Materials
T2 copper (≈ C11000), 1060 aluminum. Others on request, e.g. C10100, 6063 Al
Plating
Copper: tin, nickel, silver, gold, passivation. Aluminum: nickel, tin
Insulation
Heat-shrink, epoxy coating, PET film, Nomex, Formex, Kapton, PVC dipping
Tin-plated copper busbar
Gold-plated busbar
Generator copper ring
PVC-dipped busbar
For moving parts

Flexible connectors

They join parts that move, vibrate or carry installation tolerances in generators, transformers, switchgear, EVs and battery packs, and absorb shocks that would crack a rigid bar.

Copper foil
Contact ends diffusion-welded in one operation, then punched. Bare, tin- or silver-plated
Braided
Flat braid or round strand with cold-pressed terminals. Bare or tin-plated copper
Copper foil connector
Braided connector
Braid with copper ends
Sleeved braided connector
Low inductance

Laminated busbars

Multi-layer conductors bonded with thin insulation into one rigid part. They replace wiring harnesses in power modules and make assembly error-free.

  • Low inductance and temperature rise
  • Higher capacitance damps switching spikes
  • Compact layout saves cabinet space
  • Lower total cost than cables plus brackets
IGBT module busbar
Flat laminated busbar

Capabilities

Rated voltage0 – 5 kV
Rated current0 – 3,000 A
Flame retardancyUL 94 V-0
Insulation resistance> 20 MΩ at DC 1,000 V
Operating temperature−40 °C to +105 °C
Partial discharge< 10 pC
Temperature rise0 – 40 K
Maximum size1,200 × 700 mm (47.2 × 27.6 in)
ConductorsT2 copper, 1060 aluminum; gold, silver or tin plating, passivation
InsulationPET film, FR epoxy board, GPO-3 board
Edge sealingHeat sealing, hot-press sealing, resin coating or potting
TerminalsEmbossing, riveted or soldered bushings, bending
Ready to install

Insulated assemblies

Insulated conductors joined into one unit by heat bonding, bolting or our in-house injection-molded parts. Each assembly is dimension-checked and hi-pot tested, ready to drop into the cabinet.

Insulated busbar unit
Three-phase assembly
Not sure which fits?
Talk to an engineer →